Figure 7.

This table shows the percentage of correct answers and the average trial duration as a function of the difference in wavelength in the grating frequency comparison experiment.

spacial frequency (mm) percentage of correct answers average trial duration (seconds)
0.5 74.4±7.3 6.5±1.8
1.0 85.8±11.1 5.9±1.7
1.5 95.1±8.7 5.2±1.2
2.0 94.3±5.0 4.6±1.2
2.5 98.2±3.7 4.3±0.9
3.0 100.0±0.0 3.7±1.0
3.5 100.0±0.0 3.6±0.9
4.0 98.1±5.6 3.9±0.9
4.5 100.0±0.0 3.2±0.8
5.0 100.0±0.0 3.1±0.7